Hitachi 232437 Water Pump User Manual


 
308765 7
Setup
Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section FIRE AND EXPLOSION
HAZARD on page 5.
1. Pump: use the ground wire and clamp (supplied).
See Fig. 1. Loosen the grounding lug locknut (W)
and washer (X). Insert one end of the ground wire
(18) into the slot in lug (Z) and tighten the locknut
securely. Connect the other end of the wire to a
true earth ground.
2. Agitator (Models 232437 and 232449 only): one
end of the agitator ground wire (40, supplied) is
fastened to the agitator motor with a screw. Insert
the other end of the ground wire into the slot in lug
(Z). Insert the pump ground wire (18) as described
in step 1 and tighten the locknut (W) securely.
8238A
W
18
X
Z
40
Fig. 1
1 Models with agitator only.
1
3. Air and fluid hoses: use only electrically conductive
hoses.
4. Air compressor: follow manufacturer’s recommen-
dations.
5. Spray gun: ground through connection to a prop-
erly grounded fluid hose and pump.
6. Fluid supply container: follow your local code.
7. Object being sprayed: follow your local code.
8. Solvent pails used when flushing: follow your local
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the
pail on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding continu-
ity.
9. To maintain grounding continuity when flushing or
relieving pressure, hold a metal part of the spray
gun firmly to the side of a grounded metal pail,
then trigger the gun.