Hellenbrand TS Series Water System User Manual


 
Specications
Pipe Size: 1" 1.5"
Flow Ranges (gpm): .7 - 40 1.5 - 75
Accuracy: +/- 5% +/- 5%
Features:
Volume Display in Gallons
Hardness Display in Grains per Gallon
System Capacity Display in Kilograins
System Flow Rate Display in Gallons Per Minute
Totalizing Metering
Programmable Timed Auxiliary Output Relay
Fully Adjustable Regeneration Cycles
Program Lockout Protection
Adjustable Regeneration Times
Variable Reserve Capacity Based On Previous Water Usage History
Delayed or Immediate Regeneration
Calendar Day Override
System Diagnostic Displays
Microprocessor - Transformer supplied 115V Primary, 24V Secondary
ET Microprocessor Meter Controller
Regeneration Options
Manual control requires no electricity for operation. Opera-
tor must start and end the regeneration including backwash,
brine and rinse, and fast rinse times and manually return unit
toservice.Aoatvalveisusedtoregulatesaltusage.
Time clock control with either a 7 or 12 day timer, allows
the operator to preset regeneration time and frequency as
needed. A built-in manual override is included for increased
water usage times.
Water meter demand control systems are recommended for
those applications where daily water usage varies throughout
the year. Meter demand systems are available with either
mechanical or microprocessor based systems. Both types
of metering systems are available with either delayed or im-
mediate regeneration.
Econominder Meter
Specications
Pipe Size: 3/4" 1" 1-1/2"
Flow Ranges: .15-20 .7-40 1.5-70
Accuracy: ± 5% ± 5% ± 5%
Meter Gallon Ranges:
A) 3/4" Standard Range: 125 - 2,125 Gallons
Extended Range: 625 - 10,625 Gallons
B) 1" Standard Range: 360 - 5,100 Gallons
Extended Range: 1,800 - 25,200 Gallons
C) 1-1/2" Standard Range: 625 - 10,625 Gallons
Extended Range: 3,125 - 53,125 Gallons
A. MINERAL TANK: NSF Approved, UL Listed, Fiberglass
Reinforced Pressure Vessel Manufactured to Operate at 150
psi and 120 F.
B. DISTRIBUTOR SYSTEM:
Hub & Lateral or Bottom Stack
Distributor System for Maximum Service Flow and Minimal
Pressure Loss.
C. MINERAL:
FDA Approved, High Capacity Ion Exchange.
Resin has uniform and stable beads assuring long life, high
saltefciency,andmaximumhardnessremoval.
D. UNDERBEDDING:
Gravel Underbedding assures full
usage of mineral bed and allows for a smooth and constant
waterowforserviceandregeneration.
E. BRINE TANK:
High Density Polyethylene Brine Tank
has exceptional environmental stress crack properties. It will
not crack or rust out. Dust-tight covers keep out unwanted
impurities.
F. SALT GRID SYSTEM: Hellenbrand’sHighSaltGridSys
-
tem allows for only a minimal of salt being wetted, helping to
eliminate problems from bridging salt.
G. SAFETY BRINE VALVE:
An optional safety brine valve,
acts as a secondary shut-off in case of a failure with primary
shut-off.
TS Series
A
B
C
D
F
E
G
Typical Piping Installation
BRINE
TANK
RESIN
TANK
BRINE
LINE
DRAIN
LINE
POWER
CORD
OPTIONAL METER
MANUAL
SHUT-