Heatmaster 150 JUMBO Fan User Manual


 
24
USER GUIDE
RESETTING THE PRESSURE JET OIL OR GAS
BURNER
HM 60 N and HM Jumbo 150
the lockout indicator is situated on the burner.
HM 70 N and 100 N
the lockout indicator is situated on the burner and on the
control panel.
The red warning light indicates an operating fault.Wait five minutes
before resetting the burner.To reset :press the button located on the
burner.
If the burner does not relight, call the service engineer after ensuring
that the fault is not due to a power cut or low oil in the tank.
RESETTING THE BG 2000-S PREMIX GAS BURNER
HM 60 N BG 2000-S/60
the lockout indicator is situated on the burner.
HM 70 N BG 2000-S/70 and HM 100 N BG 2000-S/100
the lockout indicator is situated on the burner and on the
control panel.
1. Remove the burner cover.
2. Press the red button to restart the burner.
3. If the burner lights, replace the cover.
4. If the fault persists, call a service engineer.
BURNER TROUBLESHOOTING
For all burners - please refer to the relevant servicing and