Heatiator NB3933MI Indoor Fireplace User Manual


 
8 Heatilator • Novus BV-Mesh • 4031-553 Rev F • 11/07
Note:
• Illustrations re ect typical installations and are FOR
DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
Fire Risk
Provide adequate clearance:
Around air openings.
For service access.
Locate appliance away from traf c areas.
WARNING
A. Select Appliance Location
When selecting a location for your appliance it is important to
consider the required clearances to walls (See Figure 3.1).
Note: For actual appliance dimensions refer to
Section 16.
In addition to these framing dimensions, also reference the
following sections:
Clearances and Mantel Projections (Sections 3.C. and 3.D.)
Vent Clearances and Framing (Section 6)
A
A
A
C
B
B
1/2 in. (13 mm) min.
appliance
to combustibles
Alcove
Installation
C
D
Drywall
48 in.
(1219 mm)
max.
Figure 3.1 Appliance Locations
3
3
Framing and Clearances
Model A B C D
NB3630M/MI
inches 36 33-1/2 19-5/8 37
mm 914 851 498 940
NB3933M/MI
inches 39 35-1/2 19-5/8 40
mm 991 902 498 1016
NB4236M/MI
inches 42 37-5/8 19-5/8 43
mm 1067 956 498 1092
NB4842M/MI
inches 48 41-7/8 19-5/8 49
mm 1219 1064 498 1245