Heatiator CR36D Indoor Fireplace User Manual


 
19
B. Clearances
WARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles as speci ed in Fig-
ure 6.2. DO NOT pack required air spaces with insulation or other materials.
Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09
(insulation)
0 in. to level
of standoffs
Attic
Insulation
Shield
(ceiling)
(roof)
(attic)
(ceiling)
Ceiling Firestop
Offset/Return (secured
with hanger straps)
Storm Collar
Roof Flashing
1/2 in. (13 mm) to back &
side of appliance
Must have 2 in. (51 mm)
minimum clearance
to header
0 in.
to floor
2 in. (51 mm) min.
Shaded areas
represent
2 in. (51 mm) min.
air space clearance
required around pipe
Chimney air kit
attached here (not shown)
Figure 6.2 Clearances to Combustible Materials
Note: Chimney air kit is not shown, but is required in Canada.