Heatiator CB4842IR Indoor Fireplace User Manual


 
Heatilator • Caliber BV Series • 4040-262 • Rev M • 08/09 23
The diagram shows how to properly position, level, and
secure the appliance (see Figure 9.2). Nailing tabs are
provided to secure the appliance to the framing members.
Bend out nailing tabs on each side.
Place the appliance into position.
Keep nailing tabs ush with the framing.
Level the appliance from side to side and front to
back.
Shim the appliance as necessary. It is acceptable to use
wood shims underneath the appliance.
Secure the appliance to the framing by using nails or
screws through the nailing tabs.
Secure the appliance to the oor by inserting two screws
through the bottom front of the appliance.
9
Appliance Preparation
A. Install Outside Air Kit Damper Assembly

Wear protective gloves and safety glasses during installa-
tion. Sheet metal edges are sharp.
draw out-
side combustion air from:
Wall, oor or ceiling cavity.
Enclosed space such as an attic or garage.
Close proximity to exhaust vents or chimneys.
Fumes or odor may result.
The outside air kit can only be installed on the left side
of the appliance.
Refer to the installation instructions provided with the
kit.
Outside Air
Hood
Outside Air
Plate
Assembly
2 Wire Ties
Flexible Duct
(not supplied)
• Hearth & Home Technologies Inc recommends using
UL181 Class 0 or Class I rigid or flexible ducting.
• Secure flex duct with metal tape, screws or wire ties.
Figure 9.1 Outside Air Kit Installation
B. Gas and Electrical Connections
If applicable, ensure that gas and electrical connections
are installed at this time. Refer to Sections 11 (Gas Infor-
mation) and 12 (Electrical Information).
C. Secure and Level the Appliance
Prevent contact with:
Sagging or loose insulation
Insulation backing or plastic
Framing and other combustible materials
Block openings into the chase to prevent entry of blown-in
insulation. Make sure insulation and other materials are
secured.
DO NOT notch the framing around the appliance
standoffs.
Failure to maintain air space clearance may cause
overheating and re.
Figure 9.2 Proper Positioning and Securing of Appliance
Nailing Tabs