3
598-1120-04
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . Up to 180°
Electrical Load . . . . . . Up to 120 Watts Maximum
Incandescent [Up to 60 Watts
Maximum each lamp holder.]
Up to 40 Watts Maximum
Fluorescent [Up to 20 Watts
Maximum each lamp holder.]
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.
Motion
Motion
TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
Least Sensitive Most Sensitive
Sensor
The detector is most sensitive to motion across its field
of view.
Maximum Range Maximum
Coverage Angle
NOTE: Sensor has about 1
1
/
2
minutes warm up period
before it will detect motion. When first turned
on, wait about 1
1
/
2
minutes.
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
180°
70 ft.
(21 m)
8 ft.
(2.4 m)
❒ Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.
❒ Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
❒ Walk through the coverage area
noting where you are when the
lights turn on (also, the LED will
flash several times when motion
is detected). Move the sensor
head up, down, or sideways
to change the coverage area.
Keep the sensor at least
1" (2.5 cm) away from the
lamps.
❒ Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒ Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
❒ Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
Note: One minute mode is not recommended for
use with compact fluorescent bulbs.
Warning - Risk of fire. Do not aim the lamps at a
combustible surface within 3 ft. (1 m).
RANGE
10 5 1 TEST
ON-TIME
MIN MAX
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage