3
595-5498-09
TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
Avoid aiming the control at:
• Objects that change temperature rapidly, such as heat-
ing vents or air conditioners. These heat sources
could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
110°
30 ft (9.1m)
The detector is less sensitive to motion directly towards
it and more sensitive to across motion.
7ft
(2.1 m)
Maximum Range Maximum
Coverage Angle
❒ Rotate the sensor base left
and right to aim the sensor.
Adjust the sensor eye up
and down to obtain desired
coverage range.
❒ Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down,
or sideways to change the
coverage area.
❒ Set SENSITIVITY as needed.
Too much sensitivity may
increase false triggering.
❒
Set the amount of TIME the
lights stay on after motion is de-
tected (1, 5, or 10 minutes).
In the test position shown above, the light will turn
on for 5 seconds each time motion is detected dur-
ing both daylight and darkness.
SPECIFICATIONS
Range . . . . . . . . . . . . . . Up to 30 ft (9.1 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . . . Up to 110°
Electrical Load . . . . . . . . Up to 60 Watt Maximum In-
candescent
Power Requirements . . . 120 VAC, 60 Hz
Operating Modes . . . . . . TEST, AUTO and MANUAL
OVERRIDE
Time Delay . . . . . . . . . . 1, 5, 10 minutes
Sensitivity . . . . . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.
ON-TIME SENS
TEST 1 5 10 MIN MAX
Bottom of Sensor
Least Sensitive Most Sensitive
Sensor
Motion
Motion
NOTE: Sensor has a 1
1
/
2
minute calibration period
before it will detect motion. When first turned
on, wait 1
1
/
2
minutes.
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
❒ For aiming, turn the SENSITIVITY (SENS) control
to the mid position and the ON-TIME control to the
TEST position.