3
598-1164-04
SPECIFICATIONS
Range ........................... Up to 60 ft. (18.3 m); [varies with
surrounding temperature]
Sensing Angle .............. Up to 110°
Lamp ............................. 15 watt, 6 volt halogen
Battery Type .................. Sealed lead acid, 6 V 6.0 A-Hr.
On Time ........................ 30 seconds, re-triggerable
Full Charge on Time ..... Up to 1 hour
BATTERY REPLACEMENT
This solar light contains a rechargeable battery that can
be replaced if needed. To replace the battery follow the
steps below.
Battery Cover Catch Release
Battery
Cover
Positive Wire
Rechargeable
Battery
Negative Wire
Tab Slots
HeathCo LLC reserves the right to discontinue products
and to change specifications at any time without incurring
any obligation to incorporate new features in products
previously sold.
IMPORTANT: Replace lamp only with same type lamp,
20 watts or less. DO NOT reverse the battery wires.
Damage to the unit will result. Like any lead-acid
battery, this battery must be disposed of properly.
IMPORTANT: Keep sensor switch in the “OFF”
position for three days to allow the battery to fully
charge before testing.
1. Remove rear battery cover. Press in the two catch
releases on the cover and remove the cover.
2. Remove rechargeable battery. Slide battery out of case
and remove the wire connectors from the battery.
3. Replace battery. Connect the RED wire connector to
the positive (+) terminal and the BLACK wire connector
to the negative (-) terminal.
4. Replace battery cover. Insert the two tabs on the cover
into the slots on the back of the case. Press the cover
against the case until the two catch releases snap into
place.
IMPORTANT: The sealed lead-acid battery must be
recycled or disposed of properly.