Heath Zenith PF-4290 Series Home Safety Product User Manual


 
2
598-1234-02
INSTALLATION
Forbestperformance,mountthextureabout
6 feet (1.8 m) above the ground.
1. Remove
two nuts.
2. Remove
X-Bar.
Junction
Box
5. Attach X-Bar to
junction box
Duetothesizeandweightofthexture,you
mayndithelpfultohaveanassistantholdthe
xtureinplacewhileconnectingthewires.
WIRING
One Motion Light
BLACK
WHITE
Two Motion
Lights
BLACK
WHITE
Twist the junction box wires and the
xture wires together as shown below.
Secure with wire connectors. If you have
a metal junction box, you may not need
the green “pigtail”. If you are unsure about
the grounding method, consult your local
building code.
CAUTION: DO NOT connect the RED wire
unless you want to control other lights
from the motion sensor.
Black to black
White to white
MAX
MIN
3. Tighten screws
ngertight.
SENSITIVITY
4.Setsensitivityonxture
back to the mid-position.
Recommended Grounding Method
Use a green ground “pigtail” (not provided) and
twistoneendtogetherwiththebarexturewire
and the box ground wire. Secure with a wire
connector. Secure the other end of the "pigtail"
with the GND screw on the X-bar.
BLACK
WHITE
BLACK
WARNING: Turn power off at circuit
breaker.