2
598-1234-02
INSTALLATION
Forbestperformance,mountthextureabout
6 feet (1.8 m) above the ground.
1. Remove
two nuts.
2. Remove
X-Bar.
Junction
Box
5. Attach X-Bar to
junction box
Duetothesizeandweightofthexture,you
mayndithelpfultohaveanassistantholdthe
xtureinplacewhileconnectingthewires.
WIRING
One Motion Light
BLACK
WHITE
Two Motion
Lights
BLACK
WHITE
❒ Twist the junction box wires and the
xture wires together as shown below.
Secure with wire connectors. If you have
a metal junction box, you may not need
the green “pigtail”. If you are unsure about
the grounding method, consult your local
building code.
CAUTION: DO NOT connect the RED wire
unless you want to control other lights
from the motion sensor.
Black to black
White to white
MAX
MIN
3. Tighten screws
ngertight.
SENSITIVITY
4.Setsensitivityonxture
back to the mid-position.
Recommended Grounding Method
Use a green ground “pigtail” (not provided) and
twistoneendtogetherwiththebarexturewire
and the box ground wire. Secure with a wire
connector. Secure the other end of the "pigtail"
with the GND screw on the X-bar.
BLACK
WHITE
BLACK
WARNING: Turn power off at circuit
breaker.