SPECIFICATIONS
Range . . . . . . . . . . Up to 30 ft. (9.1 m)
[varies with surrounding
temperature].
Sensing Angle . . . . Up to 180°
Electrical Load . . . . See rating on fixture for
maximum wattage.
Sensor Capacity . . Up to 360 Watt (3.0
A.) Maximum Tungsten
Incandescent
Power
Requirements . . . . 120 VAC, 60 Hz
Operating Modes . . TEST, AUTO, and
MANUAL MODE
Time Delay . . . . . . 1, 5, 10 minutes
DualBrite
®
timer . . Off, 3, 6 hrs, Dusk-to-
Dawn
HeathCo LLC reserves the right to discontinue
products and to change specifications at any
time without incurring any obligation to incorpo-
rate new features in products previously sold.
SYMPTOM
Light comes
on for no ap-
parent reason.
Light stays on
continuously.
Light flashes
on and off.
POSSIBLE CAUSE
1. Light control may be sensing
small animals or automobile
traffic (Reduce sensitivity).
1. The sensor is pointed toward
a heat source like an air vent,
dryer vent, or brightly-painted
heat-reflective surface. (Reduce
sensitivity.)
2. Light control is in Manual Mode.
(Switch to Auto.)
3. Light control is in D
ualBrite
®
mode.
4. Sensitivity is set too high. (Re-
duce sensitivity.)
1. Light control is in the Test
mode and warming up.
(Flashing is normal under these
conditions).
POSSIBLE CAUSE
1. Light switch is turned off.
2. Bulb is loose or burned out.
3. Fuse is blown or circuit breaker
is turned off.
4. Daylight turn-off is in effect
(recheck after dark).
5. Incorrect circuit wiring, if this is
a new installation.
1. Light control may be installed
in a relatively dark location.
2. Light control is in Test.
(Set
control switch to an ON-TIME
position.)
SYMPTOM
Light will not
come on.
Light comes on
in daylight.
TROUBLESHOOTING GUIDE