Heath Zenith PF-4197-WH Home Safety Product User Manual


 
6
598-1167-05
The detector is less sensitive to motion di-
rectly towards it and more sensitive to across
motion.
Sensor
Motion
Least Sensitive Most Sensitive
Walk through the coverage area noting
where you are when the lights turn on.
If you need to change the sensitivity,
temporarily remove the fixture and make
the adjustment. Too much sensitivity may
increase false triggering.
Set the amount of TIME you want the light
to stay on after motion is detected. (1, 5,
or 10 minutes).
Set the amount of time after dusk you want
the lights on accent level.
TEST 1 5 10 MIN
ON-TIME
OFF 3 6 DUSK TO
HOUR DAWN
30 ft.
(9.1 m)
180°
Motion
Note: Meets the ENERGY STAR
®
guidelines
when DualBrite
®
function is off.
Switch the on-time to TEST position and
DualBrite
®
switch to the OFF position.
6 ft.
(1.8 m)
TESTING
Turn on the circuit breaker and light
switch.
Maximum Range Maximum
Coverage Angle
Avoid aiming the control at:
Pools of water or objects that change
temperature rapidly, such as heating vents
and air conditioners. These heat sources
could cause false triggering.
• Areas where pets or traffic may trigger
the control.
Nearby large, light-colored objects
reflecting daylight may trigger the shut-off
feature. Do not point other lights at the
sensor.
Note: Sensor has a 1
1
/
2
minute warm up pe-
riod before it will detect motion. When
first turned on wait 1
1
/
2
minutes.