CHIME INSTALLATION
IMPORTANT: Proper installation requires a diode on the front
door push button. See Diode Installation Instructions (page 5)
after completing steps 1 through 10 below.
Note: Electrical work must be in accordance with national and local
electrical codes. If in doubt, consult a qualified electrician.
1. Verify transformer power rating. Power must be supplied from
a 16 Volt AC, 10 Watt or a 16 Volt AC, 15 Watt transformer
(Heath
®
/Zenith models 122C, 121AC, or 125C).
2. Remove cover from existing chime.
3. Label all wires before disconnecting. Using masking tape, mark
each wire according to existing chime terminal markings.
“F” – Front Push Button Wire
“T” – Transformer Wire
“R” – Rear Push Button Wire*
4. Disconnect all wires from existing chime.
5. Remove existing chime base from wall.
6. Determine chime mounting location. IMPORTANT: This chime
requires more mounting surface than most other chimes. Use
the dimensions in Figure 1 to help determine the proper loca-
tion of the chime. If chime will not fit in the same location as
the existing chime, then contact a licensed electrician to move
the existing wiring to a more suitable location.
Illustrations may vary from actual chime unit.
Figure 1 - Chime Dimensions
Continued
51
3
/
8
"
58
1
/
2
"
12
11
/
16
"
Wire Entrance Hole
Mounting
Hole (x2)