Heath Zenith 2LBL3 Home Safety Product User Manual


 
5
598-1325-00
SPECIFICATIONS
Horizontal Range . . . . Up to 70 ft. (21 m); 100 ft.
(30.5 m) with Range Boost.
[varies with surrounding
temperature]
Vertical Range . . . . . . Up to 15 ft. (4.6 m)
Sensing Angle . . . . . . Up to 240° horizontal. Up to 80°
Vertical
Electrical Load . . . . . . Up to 200 Watts Maximum In-
candescent (Up to 100 Watts
Maximum each lamp holder.)
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 20 minutes
DualBrite
®
Timer . . . . Off, 3, 6 hours, Dusk-to-Dawn
Replacement lamp . . . T4 100W, G8 halogen bi-pin 120
VAC
POSSIBLE CAUSE
1. A lamp is positioned too close to the
sensor or pointed at nearby objects
that cause heat to trigger the sensor.
(Reposition the lamp away from the
sensor or nearby objects).
2. Light control is pointed toward a heat
source like an air vent, dryer vent, or
brightly-painted heat-reflective surface.
(Reposition sensor. Reduce Range).
3. Light control is in Manual Mode. (Switch
to Auto).
1. Heat or light from the lamps may be
turning the light control on and off.
(Reposition the lamps away from the
sensor).
2. Heat being reflected from other objects
may be affecting the sensor. (Reposi-
tion sensor).
3. Light control is in the Test mode and
warming up. (Flashing is normal under
these conditions. Turn Boost off).
1. Sensor is detecting its own lights.
(Reposition lamps to keep area below
the sensor relatively dark).
SYMPTOM
Lights stay
on continu-
ously.
Lights flash
on and off.
Lights flash
once, then
stay off in
Manual Mode.
SYMPTOM
Lights will
not come
on.
Lights come
on in day-
light.
Lights come
on for no
apparent
reason.
Lights turn
off too late
in Dusk-
to-Dawn
setting.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Light is loose or burned out.
3. Fuse is blown or circuit breaker is turned
off.
4. Daylight turnoff is in effect (recheck after
dark).
5. Incorrect circuit wiring, if this is a new
installation.
6. Re-aim the sensor to cover desired area.
1. Light control may be installed in a rela-
tively dark location.
2. Light control is in Test. (Set control switch
to an ON-TIME position).
1. Light control may be sensing small
animals or automobile traffic (re-aim
sensor).
2. Range is set too high. (Reduce Range
setting).
3. D
ualBrite
®
Timer is on.
1. Sensor is in a relatively dark location.
(Relocate sensor, or use 3 hr or 6 hr
setting).
TROUBLESHOOTING GUIDE
1 YEAR LIMITED WARRANTY:
Should this product fail to perform satisfactorily due to a defect or poor workmanship within one year of date of
purchase, return it to the place of purchase and it will be replaced, free of charge. Incidental or consequential
damages are excluded from this warranty. Light bulbs are not covered.
Manufactured for Grainger International, Inc.
Lake Forest, IL 60045