Heath Zenith 2LBL3 Home Safety Product User Manual


 
4
598-1325-00
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
MAX
MIN
RANGE
ON-TIME
DUAL BRITE™
TEST 1 5 20
MINUTES
OFF
3
6
DUSK TO
DAWN HOUR
B
O
O
S
T
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
1
/
2
minute warm up period
before it will detect motion. When first turned
on, wait 1
1
/
2
minutes.
Turn the RANGE control to the medium position
(halfway between MIN and MAX), DualBrite
®
to OFF,
and the ON-TIME control to the TEST position.
Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several
times when motion is detect-
ed). Move the sensor head up,
down, or sideways to change
the coverage area. Keep the
sensor at least 2" (51 mm)
away from the lamps.
Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
Secure the sensor head
by tightening the clamp
screw. Do not overtighten the
screw.
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 20 minutes).
Set the DualBrite
®
switch to the amount of time after
dusk you want the lights on at low level (Off, 3, 6
Hrs., Dusk-to-Dawn).
WARNING - Risk of fire. Do not aim the bulbs
at a combustible surface within 3 ft. (1 m).
Maximum
Maximum Range Coverage Angle
15 ft.
(4.6 m)
70 ft. 100 ft.
(21 m) (30.5 m)
Boosted
240°
DualZone
DualZone
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
Motion
Motion
Sensor
DualZoneDualZone
NOTE: DualZone™ adds a zone of detection under
the motion sensor. DualZone™ requires no additional
adjustment and operates in conjuction with the for-
ward-looking sensor.
Least Sensitive Most Sensitive
NOTE:
If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.