Heat & Glo LifeStyle TIARAP-CES Gas Heater User Manual


 
Page 12
August 1, 2008
Heat & Glo · Tiara Petite B · 7026-101K
F. Horizontal Termination
Figure 5.3
Type A - Up & Out Installation
90° ELBOW
PIPE LENGTH
PIPE LENGTH
TERMINATION CAP
WALL THIMBLE
WALL THIMBLE COVER
CENTER LINE
WALL THIMBLE
45°
ELBOW
2 in. (51mm) CLEARANCE FROM
STOVE CORNER TO
COMBUSTILE WALL
2 in. (51mm) CLEARANCE FROM STOVE CORNER TO COMBUSTIBLE
WALL
TERMINATION CAP
CENTER LINE
16-5/8 in.
WALL THIMBLE
WALL THIMBLE COVER
(42 cm)
Type C - 45° Elbow in Corner Installation
Type B - Straight Out Installation
Female Locking Lugs
Male Locking Lugs
Step 1.
Determine the desired location of the appliance. Check to
ensure that wall studs or roof rafters are not in the way when
the venting system is attached. If this is the case, you may
want to adjust the location of the appliance.
Figure 5.4
Step 2.
Direct vent pipe is designed with a locking connection. To
connect the venting system to the appliance flue outlet, a
twist-lock adapter is built into the appliance at the factory.
Wall thickness may vary. Remember to include wall thickness
in minimum clearances when figuring venting lengths for
your installation needs.
Note: Female ends of direct vent pipe/elbows are designed
to slide straight onto the male ends of adjacent pipes by
orienting the pipe indentations so they match and slide into
the entry slots on the male ends, see Figure 5.4. Push
the pipe sections completely together, then twist-lock one
section clockwise approximately one-quarter turn, until the
two sections are fully locked. The female locking lugs may
not be visible from the outside. They may be located by
examining the inside of the female ends.
Fire Risk.
Explosion Risk.
Combustion Fume Risk.
Use vent run supports per installation instructions.
Connect vent sections per installation instructions.
Maintain all clearances to combustibles.
Do NOT allow vent to sag below connection
point to appliance.
Maintain speci ed slope (if required).
WARNING
Improper support may allow vent to sag or separate.
Fire Hazard.
Exhaust Fume Risk.
Impaired Performance of Appliance.
WARNING
Ensure vent components are locked together correctly.
Pipe may separate if not properly joined.