Heat & Glo LifeStyle SL-950TV-IPI-E Indoor Fireplace User Manual


 
Heat & Glo • SL-550 / 750 / 950TV-IPI-E • 2119-900 Rev. J • 12/09 7
B. Tempered Glass Speci cations
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous loca-
tions such as bathtub enclosures as de ned by the Con-
sumer Product Safety Commission (CPSC). The tempered
glass has been tested and certi ed to the requirements
of ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing
Certi cation Council SGCC# 1595 and 1597. Architectur-
al Testing, Inc. Reports 02-31919.01 and 02-31917.01).
This statement is in compliance with CPSC 16 CFR Sec-
tion 1201.5 “Certi cation and labeling requirements”
which refers to 15 U.S. Code (USC) 2063 stating “…Such
certi cate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
C. BTU Speci cationsA. Appliance Certi cation
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
1
1
Listing and Code Approvals
MODELS: SL-550TV-IPI-E, SL-750TV-IPI-E, SL-950TV-IPI-E
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: B-Vent Gas Appliance
STANDARD: ANSI Z21.50-2007 • CSA 2.22-2007
Model(s)
U.S. (0-2000 ft.) or Canada (2000-4500 ft.)
Maximum
Input BTU/h
Minimum
Input BTU/h
Ori ce
Size
(DMS)
SL-550TV-IPI-E
US
21,100 14,700 44
CAN
18,990 13,230 45
SL-550TV-IPI-E (LP)
US
20,000 14,300 55
CAN
18,000 12,870 56
SL-750TV-IPI-E
US
24,800 17,700 42
CAN
22,320 15,930 43
SL-750TV-IPI-E (LP)
US
23,200 17,300 54
CAN
20,880 15,570 55
SL-950TV-IPI-E
US
30,900 21,300 37
CAN
27,810 19,170 38
SL-950TV-IPI-E (LP)
US
30,700 22,500 52
CAN
27,630 20,250 53
This product is listed to ANSI standards for “Vented Gas
Fireplaces” and “Gas Fired Appliances for Use at High
Altitudes”.
May be installed in a sleeping room when the provisions
for combustion, ventilation and dilution air are met per the
requirements of ANSI 223.1/NFPA 54 National Fuel Gas
Code. In Canada, installation in a sleeping room requires
installation with a thermostat certi ed for use with this prod-
uct. Consult your local authorities having jurisdiction.
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
This model (natural gas and propane) can be installed in
a bedroom (in Canada) if a thermostat (Model WH-STAT)
is installed with the unit. Consult local code authorities.
Detailed installation instructions for Model WH-STAT are
included with the kit.