Heat & Glo LifeStyle EVEREST Indoor Fireplace User Manual


 
Heat & Glo • Everest • 750-900 Rev. L • 1/06
21
!
Step 4. Positioning, Leveling, and
Securing the Fireplace
!
!
The diagram below shows how to properly position, level,
and secure the fireplace.
Figure 20. Proper Positioning, Leveling, and
Securing of a Fireplace
Figure 21. Intermittent Pilot Ignition
NAILING TABS
(BOTH SIDES)
Step 5. The Gas Control Systems
WARNING: THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.
Intermittent Pilot Ignition (IPI) System
The gas control system used with this model is Intermittent
Pilot Ignition (IPI). This system includes a 3V control valve,
electronic module, and intermittent pilot.
WARNING: CONTINUOUS 110-120 VAC SER-
VICE MUST BE WIRED TO THE FIREPLACE
JUNCTION BOX.
WARNING: DIRECT VENT PROPANE MODELS
WITH IPI CONTROL SYSTEMS CANNOT BE
USED IN CANADA.
1. Place the fireplace into position.
2. Level the fireplace from side to side and from front to
back.
3. Shim the fireplace with non-combustible material, such
as sheet metal, as necessary.
4. Secure the fireplace to the framing by nailing or screwing.