Figure 10. Vertical Baffle
1. Attach the First Vent Component to the
Starting Collars
To attach the first vent component to the starting collars
of the fireplace:
Make sure that the fireplace gasket supplied with the
fireplace seals between the first component and the out-
er fireplace wrap.
Refer to Cinch Pipe and Termination Cap installation in-
structions.
B. Installing Vent Components
If your vertical vent component is over 10 feet, you may
want to install the included vertical baffle to improve flame
appearance. Vertical baffle is located in the bag containing
the instruction manual. Center the vertical baffle on the five
inch flue being used, and with self tapping screws secure
the baffle to the inside of the firebox (see Figure 10).
With vent runs of 30 feet or more without elbows, an
additional baffle (SRV750-152) is to be used with the
supplied baffle. This is a service part and is to be purchased
separately.
V
ERTICAL
BAFFLE
5” EXHAUST
PIPE
2. Assembling Vent Sections
Refer to Cinch Pipe and Termination Cap installation in-
structions.
!
WARNING: ENSURE THAT THE FIBERGLASS
GASKET SUPPLIED WITH THE FIREPLACE
SEALS BETWEEN THE FIRST VENT COMPONENT
AND THE OUTER FIREPLACE WRAP.
If the installation is for a termination cap attached directly
to the fireplace, skip to the sections, Install Firestops and
Vent Termination.