Heat & Glo LifeStyle CERONA-36 Indoor Fireplace User Manual


 
Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev. F • 04/0816
Figure 5.6
1. Top Vent - Horizontal Termination - (continued)
Three Elbows
2. Top Vent - Vertical Termination
Straight up Vertical Venting
V
1
= 50 ft. Max. (15.2 m)
V
1
Minimum H
1
Maximum
Cerona-36 ONLY
1/2 ft 152 mm 3 ft 914 mm
1 ft 305 mm 4 ft 1.2 m
2 ft 610 mm 7 ft 2.1 m
3 ft 914 mm 10 ft 3.0 m
4 ft 1.2 m 13 4.0 m
5 ft 1.5 m 16 4.9 m
6 ft 1.8 m 17 5.2 m
7 ft 2.1 m 22 6.7 m
H
1
+ H
2
= 22 ft. (6.7 m) Max.
V
1
+ V
2
+ H
1
+ H
2
= 62 ft. (18.9 m) Max.
H
2
H
1
V
2
V
1
CAP
V
1
Figure 5.5
Note: On vertical venting con gurations
install the ue restrictor found in the
appliance manual bag. Follow flue
restrictor instructions in Section 7D.
Note: Must have
a minimum verti-
cal vent before
attaching a 90º
elbow to the unit.
See chart.
Minimal Vertical Vent
Model ft. mm
Cerona-36 1/2 152
Cerona-42 1 305