Heat & Glo LifeStyle AT-ZC Indoor Fireplace User Manual


 
17
3. Run the low voltage lead wires up the back of the right
side of the surround and secure them with the three
wire ties found there. Re-connect the low voltage wires
to the short wires of the ON/OFF switch.
4. Position surround on face of unit by hooking surround
behind top ledge on unit. Then push flush on unit and
secure by bending three holding tabs downward.
NOTE: PLACE THE THREE INSULATION PIECES
INTO THE CAVITIES AT THE BACK OF THE
SURROUND BEFORE POSITIONING THE INSERT
INTO THE FACTORY-BUILT OR MASONRY
FIREPLACE. THIS INSULATION WILL HELP SEAL
FOR COLD AIR LEAKS.
Figure 13
Figure 13 shows the minimum vertical and corresponding
maximum horizontal dimensions of mantels or other
combustible projections above the gas fireplace.
MANTEL
TOP OF UNIT
12” MAX.
12” MAX.