Heat & Glo LifeStyle 6000 XLS Indoor Fireplace User Manual


 
22
The diagram below shows how to properly position,
level, and secure the fireplace.
1. Place the fireplace
into position.
2. Level the fireplace
from side to side and
from front to back.
3. Shim the fireplace
with non-combus-
tible material, such
as sheet metal, as
necessary.
4. Secure the fireplace
to the framing by
nailing or screwing
Figure 21. Proper Positioning, Leveling, and
Securing of a Fireplace
Step 5
The Gas Control
Systems
WARNING
THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.
Two types of gas control systems are used with
these models: Standing Pilot Ignition and Direct
Spark Ignition (DSI). Model 6000XLS has Standing
Pilot Ignition only.
Standing Pilot Ignition System
This system includes millivolt control valve, standing
pilot, thermopile/thermocouple flame sensor, and
piezo ignitor.
WARNING
110-120 VAC MUST NEVER BE
CONNECTED TO A CONTROL VALVE
IN A MILLIVOLT SYSTEM.
Direct Spark Ignition (DSI) System
This system includes a 24V control valve, electronic
module, transformer, and spark ignitor/flame sensor.
WARNING
110-120 VAC MUST BE WIRED TO THE
FIREPLACE JUNCTION BOX IN A DSI
SYSTEM.
WARNING
DIRECT VENT PROPANE MODELS
WITH DSI CONTROL SYSTEMS
CANNOT BE USED IN CANADA.
Step 4
Positioning,
Leveling, and
Securing the
Fireplace