Heat Controller VMC24SB-1/VMH24SB-1 Heat Pump User Manual


 
- 43 -
Only for training and service purposes
Part 4 Trouble Shooting
Turn on the main power.
When in air circulation mode, compressor/outdoor fan is stopped.
Turn off main power.
Check the electrical wiring diagram of Outdoor side.
Check the open or short of connecting wires between Indoor and Outdoor.
Check the sensor for Indoor temperature is attatched as close as to be effected by the
themperature of Heat Exchange (EVA.)
When displaying Error code, refer to the trouble shooting guide.
Check the main power source.(AC 208V~230V)
Check the trouble shooting guide error code 21,26.
Check that CN_FAN(A,B) supplied voltage to outdoor PCB is about AC 208V~230V.
Using the remote controller, set the indoor set point to at least 15˚C(5˚F) less than the
indoor air temperature.
The Compressor/Outdoor Fan does not operate (18, 24, 30kBtu/h Model)
Trouble 4