Heat Controller MSS-018B/A Air Conditioner User Manual


 
0
5. Soft
Dry
Operation
Mode
0
"
During
Soft
Dry
Operation,
the
compressor
ON
temperature
is
the
setting
temperature
plus
2°F,
the
compres-
sor
OFF
temperature
is
the
setting
temperature
minus
1
°F.
"
When
the
room
temperature
rises
over
the
compressor
ON
temperature,
the
operation
mode
is
switched
to
the
Cooling
operation.
"
When
the
room
temperature
falls
between
the
compressor
ON
temperature
and
OFF
temperature,
the
opera-
tion
mode
is
switched
to
the
Soft
Dry
Operation.
*The
operation
diagram
Is
shown
below.
INTAKE
AIR
TE
ML
Cooing
Operation
G0*9
Soft
Dry
Operation
OpWAM
SETTING
TEMP.
+2°F
(Compressor
ON)
manmm
a
einýs
SETTING
TEMP.
-1°F
(Compressor
OFF)
min
3rrinýs
tOmnýs
p
rLies
3mintes
mazmrn
mi
INDOOR
FAN
SPEED
Selecting
fan
speed
Low
Low Low
Selecting
fan
speed
Low
Low
COMPRESSOR
ON
OFF
ON
OFF
ON
OFF
ON
-17-