Heat Controller MSH-024B/A Air Conditioner User Manual


 
"
"
Cooling
&
Heating
Models
INDOOR
UNIT
HEAT
EXCHANGER
(EVAPORATOR)
I
/
\
i
f
HEAT
EXCHANGER
(CONDENSER)
REVERSING
VALVE
1
.-
COOLING
.4
--
HEATING
Pipe
size(Diametero)
Piping
length
Elevation
MO
E
D
L
Gas
Liquid
Rated
Max
Rated
Max
9k,
12k
(Camay
a
Heating)
1/2"
1/4"
7.62m(25ft)
15m(50ft)
5m(16ft)
8m(26tt)
18k,
24k
(CodkV
a
Heating)
5/8"
g/8
7.62m(25ft)
15m(50ft)
Sm(16ft)
8m(26ft)
For
installation
over
rated,
'a
proper
ant"
of
refrigerant
should
be
added
for
each
foot.
of
Ex)
18K
When
installed
at
a
distance
of
3011t,
1.5
Oz
of
a
proper
quantity
refrigerant
refrigerant
should
be
added.
9k,
12k
0.2
Oz
(30-25)
x
0.302
=1.5
Oz
of
refrigerant
to add
18k,
24k
0.3 Oz
Unit
precharged
for
25ft. line
sets.
-10-
OUTDOOR
UNIT
CAPILLARYTUBE
f-
CHECKVALVE
GAS
SIDE
----º
COMPRESSOR
"
0