Heat Controller DMH18DB-1 Air Conditioner User Manual


 
26 Multi type Air Conditioner
Connecting the Cable between Indoor Unit and Outdoor Unit
Connect the cable to the Outdoor unit.
1. Remove the cover control from the unit by loosening
the screw.
Connect the wires to the terminals on the control
board individually as the following.
2. Secure the cable into the control board with the strain
relief clamp.
3. Refix the cover control to the original position with the
screw.
:
1. Separately wire the high and low voltage line.
2. Use heat-proof electrical wiring capable of withstanding temperature up to 75°C(167°F).
3. Use outdoor and waterproof connection cable rated more than 300V for the connection between indoor and out-
door unit. (For example, Type SJOW)
WARNING:
Be sure to comply with local codes while running the wire from the indoor unit to the outdoor
unit(size of wire and wiring method, etc).
Every wire must be connected firmly.
No wire should be allowed to touch refrigerant tubing, the compressor or any moving parts.
NOTICE
Outdoor unit
Over 5mm
Holder for
power supply
cord
Connecting
cable
Cover control
Terminal block
Power supply
cable
A-UNIT
4321
B-UNIT
4321
43214321LN
Terminal BLOCK
Power Source
208/230V AC
(High voltage)
Outdoor side
Connecting cable(Low voltage)
Indoor A-UNITIndoor A-UNIT Indoor B-UNITIndoor B-UNIT