Wall Mounted Multi-Zone Split System Air Conditioner
Installation
The wall you select should be strong and solid enough to
prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a concrete wall,
use anchor bolts.
• Mount the installation plate horizontally by aligning the
centerline using a level.
2. Measure the wall and mark the centerline. It is also
important to use caution regarding the location of the
installation plate, as routing the wiring through the wall is
typically done in this application. Drilling the hole through
the wall for piping connections must be done safely.
Installing Installation Plate(Standard Type)
Installation Plate
Type "A" screw
Chassis
Hook
Installation plate
Left rear piping Right rear piping
Ø70mm
Ø70mm
D
B
A
C
• Drill the piping hole with a Ø 70 mm (Ø 2.75 inch) hole core drill. Drill the piping hole at either the right or the left
with the hole slightly slanted to the outdoor side.
Drilling the hole in the wall
5-7 mm
(0.2"~0.3")
Indoor
WALL
Outdoor
ABCD
9 kBtu/h 50(1.97) 105(4.13) 59(2.32) 105(4.13)
12 kBtu/h 65(2.56) 110(4.33) 85(3.35) 110(4.33)
CHASSIS