Heat Controller B-MMH12FA-1 Air Conditioner User Manual


 
- 20 -
Wall Mounted Multi-Zone Split System Air Conditioner
Installation
Selecting the best location
Indoor unit
1. Do not have any heat or steam near the unit.
2. Select a place where there are no obstacles in front
of the unit.
3. Make sure that condensation drainage can be conve-
niently routed away.
4. Do not install near a doorway.
5.
Ensure the unit is unobstructed, allow proper space on all sides
according to the arrows and distance measurements in the figures.
6. Use a metal detector or stud finder to locate studs to
prevent unnecessary damage to the wall.
Outdoor unit
1. If an awning is built over the unit to prevent direct
sunlight or rain exposure, make sure that heat radia-
tion from the condenser is not restricted.
2.
Ensure the unit is unobstructed, allow proper space on all sides
according to the arrows and distance measurements in the figures.
3. Do not place animals and plants in the path of the
warm air.
4. Take the air conditioner weight into account and
select a place where noise and vibration are mini-
mum.
5.
Select a place so that the warm air and sound from
the air conditioner does not disturb neighbors.
Rooftop Installations:
If the outdoor unit is installed on a roof structure, be
sure to level the unit. Ensure the roof structure and
anchoring method are adequate for the unit location.
Consult local codes regarding rooftop mounting.
More than 20 cm
(7.9 inch)
More than 10 cm
(3.9 inch)
More than 10 cm
(3.9 inch)
More than 2.4m
(8 ft)
more than 70 cm
(27.6 inch)
more than 30 cm
(11.8 inch)
more than 30 cm
(11.8 inch)
more than 60 cm
(23.6 inch)
more than 70 cm
(27.6 inch)
more than 60 cm
(23.6 inch)
more than 30 cm
(11.8 inch)
more than 30 cm
(11.8 inch)
CAUTION: Install the indoor unit
on the wall where the height from
the floors more than 2.4 m (8 ft).
18 / 24 kBtu/h
36 kBtu/h