NOTE: A listed (and Commonwealth of Massachusetts
approved) 1/2 inch (13mm) T-handle manual shut-off valve and
exible gas connector are connected to the 1/2 inch (13mm)
control valve inlet.
If substituting for these components, please consult
local codes for compliance.
NOTE: The gap between the supply piping and gas access
hole may be plugged with non-combustible insulation to prevent
cold air in ltration.
C. Gas Connection
NOTE: Have the gas supply line installed in accordance with
local building codes, if any. If not, follow ANSI Z223.1. Instal-
lation should be done by a quali ed installer approved and/or
licensed as required by the locality. (In the Commonwealth of
Massachusetts, installation must be performed by a licensed
plumber or gas tter.)
Leak test all gas line joints and the gas control valve prior
to and after starting the appliance.
Before making the gas connection, ensure that the appliance
you are installing is designed for the type of gas being
supplied. This information can be found on the ratings label
under the appliance. If the appliance has been converted
to propane (LP), the valve cover should have a label stating
that the appliance has been converted to propane.
Connect the gas line at the 3/8 in. (10mm) pipe connector
on the valve at the back of appliance. We recommend
connecting the appliance with an approved flex gas line.
If flex gas lines are not approved in your area, you must
connect a hard pipe to the gas hookup.
You must supply a manual shut-off valve in a visible location
within 3 ft. (914mm) of the appliance.
WARNING
Gas Leak Risk.
• Support control when attaching pipe to
prevent bending gas line.
HIGH ALTITUDE INSTALLATIONS
Omni-Test Laboratories, Inc. listed gas appliances are tested and
approved without requiring changes for elevations from 0 to 2000
feet in the U.S.A. and 0 to 4500 feet in Canada.
When installing this appliance at an elevation above 2000 feet,
it may be necessary to decrease the input rating by changing
the existing burner ori ce to a smaller size. Input rate should be
reduced by 4% for each 1000 feet above a 2000 foot elevation
in the U.S.A. If the heating value of the gas has been reduced,
these rules do not apply. To identify the proper ori ce size, check
with the local gas utility.
If installing this appliance at an elevation above 4500 feet (in
Canada), check with local authorities.
A small amount of air will be in the gas supply lines. When
rst lighting appliance it will take a short time for air to
purge from lines. When purging is complete the appliance
will light and operate normally.
Air only needs to be purged again if gas valve has been
turned to the OFF position.
WARNING
Fire hazard.
Do NOT change the valve settings.
This valve has been preset at the factory.
Changing valve settings may result in re
hazard or bodily injury.
WARNING
Fire Risk or Explosion Hazard.
Gas build-up during line purge may ignite.
Purge should be performed by a quali ed
technician.
• Ensure adequate ventilation.
Ensure there are no ignition sources such
as sparks or open ame.
WARNING
CHECK FOR GAS LEAKS
Explosion Risk.
Fire Risk.
Asphyxiation Risk.
• Check the ttings and connections
Do not use open ame.
After the gas line installation is complete, all
connections must be tightened and checked
for leaks with a commercially-available, non-
corrosive leak check solution. Be sure to rinse
off all leak check solution following testing.
Fittings and connections may have loosened during
shipping and handling.