Hearth and Home Technologies SL-550TRSI-AUE Electric Heater User Manual


 
23
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06
Figure 30.
IGNITION
MODULE
(6V)
ON/OFF
WALL SWITCH
VALVE
FLAME SPARKER/
SENSOR
ANT.
REMOTE
CONTROL
HOTNEUTRAL
GROUND
BATTERY PORT
VALVE
PILOT
IGNITION MODULE
6VDC
ON/OFF
SWITCH
THERMOCOUPLE
BLOCK
(CONNECTED TO
BACK OF VALVE)
GAS LINE
CONNECTED TO
BACK OF VALVE
PLUG IN
WARNING
1.4 IGNITION SYSTEM WIRING
This gas fireplace is equipped with an electronic igni-
tion system which operates on a 6 volt system.
This appliance requires 240 VAC to be wired to the
factory installed junction box. Check factory installed
power cord for damage before using .
Shock Risk
Replace damaged wire with type
105
O
C rated wire.
Wire must have high temperature
insulation.
CAUTION
Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation
after servicing.