Hearth and Home Technologies SL-550TR-E Indoor Fireplace User Manual


 
Heat & Glo • SL-550 / 750 / 950TR-E • 2118-900 Rev. L • 11/0832
Figure 7.10
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
V
2
Top Vent - Vertical Termination
Venting with 3 elbows
V
1
MIN.
SL-550TR-E SL-750TR-E SL-950TR-E
H MAX. H MAX. H MAX. V
2
V
1
+ V
2
MIN.
90 Elbow 1/2 ft. 152 mm 1/2 ft. 152 mm 0 ft. 0 mm * *
1/2 ft. 152 mm 1 ft. 305 mm 1 ft. 305 mm 1 ft. 305 mm * *
1-1/2 ft. 457 mm 2 ft. 610 mm 2 ft. 610 mm 2 ft. 610 mm * *
2-1/2 ft. 762 mm 4 ft. 1.2 m 4 ft. 1.2 m 4 ft. 1.2 m * *
3-1/2 ft. 1.1 m 6 ft. 1.8 m 6 ft. 1.8 m 6 ft. 1.8 m * *
4-1/2 ft. 1.4 m 14 ft. 4.3 m 14 ft. 4.3 m 14 ft. 4.3 m * *
H MAX. =14 ft. (4.6 m)
V
1
+ V
2
+ H
1
+ H
2
MAX. = 40 ft. (12.2 m)
* No speci c restrictions on this value EXCEPT V
1
+ V
2
+ H
1
+ H
2
cannot exceed 40 ft. (12.2 m)
Note: Use SLP Series
components only.
Note: There MUST be a 25%
reduction in total H when using
ex vent except when using the
simple up and out installation
(see Figure 7.3).