Hearth and Home Technologies SL-550TR-E Indoor Fireplace User Manual


 
Heat & Glo • SL-550 / 750 / 950TR-E • 2118-900 Rev. L • 11/08 31
Figure 7.9
H
1
V
1
V
2
Top Vent - Vertical Termination
Venting with 2 elbows
V
1
MIN.
SL-550TR-E SL-750TR-E SL-950TR-E
H MAX. H MAX. H MAX. V
2
V
1
+ V
2
MIN.
90 Elbow 1-1/2 ft. 457 mm 1-1/2 ft. 457 mm 1 ft. 305 mm * *
1/2 ft. 152 mm 2 ft. 610 mm 2 ft. 610 mm 2 ft. 610 mm * *
1-1/2 ft. 457 mm 3 ft. 914 mm 3 ft. 914 mm 3 ft. 914 mm * *
2-1/2 ft. 762 mm 5 ft. 1.5 m 5 ft. 1.5 m 5 ft. 1.5 m * *
3-1/2 ft. 1.1 m 7 ft. 2.1 m 7 ft. 2.1 m 7 ft. 2.1 m * *
4-1/2 ft. 1.4 m 15 ft. 4.6 m 15 ft. 4.6 m 15 ft. 4.6 m * *
H MAX. =15 ft. (4.6 m)
V
1
+ V
2
+ H MAX. = 40 ft. (12.2 m)
* No speci c restrictions on this value EXCEPT V
1
+ V
2
+ H cannot exceed 40 ft. (12.2 m)
Note: Use SLP Series
components only.
Note: There MUST be a 25%
reduction in total H when using
ex vent except when using the
simple up and out installation
(see Figure 7.3).