4 Hearth & Home Technologies Inc. • SFE-35 • 4050-313 Rev C • 01/08
A Unpacking the Unit
Carefully remove packaging from the unit. The front screen
is held in place with four Phillips head screws. To remove
the screen, extract the screws. Grasp the screen frame and
pull out.
B. Locating Your Electric Fireplace
Your new electric fi replace may be installed virtually
anywhere in your home. However, when choosing a location
ensure that the general instructions are followed. For best
results, install out of direct sunlight.
Power supply service must be either completed or placed
within the heater prior to fi nishing to avoid reconstruction.
Protective cover may stay on during framing, but must be
removed before fi nal fi nishing. Once fi nal fi nishing has been
completed, the protective cover can be used to protect the
heater until fi nal installation is complete.
C. Clearance to Combustibles
Sides . . . . . . . . . . . . . . . . . . . . . . . . . . .0 in. (0 mm)
Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 in. (0 mm)
Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 in. (0 mm)
Back . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 in. (0 mm)
D. Framing
• Choose a fireplace location and frame as shown in
Figure 2.1.
• Frame in the fi replace with a header across the top.
• It is important to allow for fi nished face when setting the
depth of the frame.
• If a hearth system or raised hearth is to be installed, the
unit MUST be raised to provide service access and use
of optional fronts.
• The fi replace can now be positioned in the opening.
• Level it with shims if necessary, and attach the unit to the
frame using the nailing fl anges provided.
F. Hardwire Electrical Connections
Note: All wiring must be completed prior to fi nishing the
unit.
For supply connections use No. 14 AWG or larger wires. Use
copper wire only. Connect only to a 15 AMP branch circuit.
A dedicated circuit is recommended as other appliances on
the circuit may cause the breaker to trip or fuse to blow
when the heater is operating.
• Remove the screws securing the junction block cover.
• Wire to a properly grounded, 120 volt, 60 Hz, 15 AMP
circuit
• Ensure all junction block connections are tight.
• Replace the cover and retaining screws.
• Plug in the IEC-320-C14 power plug to the IEC-320-C13
power inlet located on the upper right side of the unit.
• All components and wiring may be inspected by removing
the top inter-panel through the fi replace front opening.
G. Wall Switch and Thermostat Connections
The Optional Wall Switch 4050-309 contains two single pole
switches. (LEVITON 5634 Series or equal)
The Optional Wall Thermostat is a low voltage mechanical
type. (Columbus Electric RK120EAA or equal)
Maximum run distance is 30 ft. (9.14 m) with 20 gauge
solid copper low voltage thermostat wire. Connect per the
electrical wiring diagram on page 7.
H. Finishing
Combustible or non-combustible materials may be used to
fi nish up to the fi replace opening.
Note: ensure that you leave adequate room to remove and
replace the front screen or optional front.
WARNING! Do NOT use this appliance if any part has
been under water. Immediately call a qualifi ed service
technician to inspect and to replace any part of the electri-
cal system if necessary.
E. Electrical Specifi cations
Voltage . . . . . . . . . . . . . . . . . . . . . . 120 V AC, 60 Hz
Total Amps . . . . . . . . . . . . . . . . . . . . . . . . . .9.6 AMP
Total Watts . . . . . . . . . . . . . . . . . . . . . . . 1050 Watts
Heater Rating . . . . . . . . . . . . .1000 Watts/3415 BTU
WARNING! Electrical wiring must comply with local
building codes and other applicable regulations to
reduce the risk of fi re, electrical shock and injury.
WARNING! Do NOT connect the optional low voltage
switch and/or thermostat to 120 volt branch circuit.