Hearth and Home Technologies QFP44 Indoor Fireplace User Manual


 
Quadra-Fire • QFP44 • 4051-300 • Rev N • 11/08 45
A. Fuel Conversion
Make sure the appliance is compatible with available
gas types.
Conversions must be made by a qualified service
technician using Hearth & Home Technologies specifi ed
and approved parts.
11
11
Gas Information
Turn control knob on the valve to OFF position.
Remove glass assembly (see Figure 14.A)
(Remove logs, grate, and ember bed if already
installed.)
Remove 2 screws holding pilot bracket to burner. See
Figure 11.1.
Kit contents:
Pilot injector #35
Burner orifi ce
Red pin
Conversion Label
Tools Required:
#2 phillips screwdriver
Straight screwdriver
5/32 allen wrench
3/8 & 11/16 wrenches
Figure 11.1 Remove Pilot Screws
Remove 4 screws holding Burner in place and remove
burner. See Figure 11.2.
Figure 11.2 Remove Burner Screws
Using a 3/8 wrench, unscrew and remove rear orifi ce
and discard. See Figure 11.3.
Figure 11.3 Remove Burner Orifi ce
Unscrew and remove front orifi ce #46 and install in
rear.
Install new orifi ce #56 in front.
Open air shutters to fully open. See Figure 11.4.
Replace burner and screws holding it in place.
Figure 11.4 Adjusting Air Shutter
Note: Gas conversions should only be performed by a
qualifi ed service person, and/or where required by state
and local codes, licensed installer/service technician. In
the Commonwealth of Massachusetts, installation must
be performed by a licensed plumber or gas fi tter.
Converting to LP Gas