Hearth and Home Technologies II-B Indoor Fireplace User Manual


 
Heat & Glo LifeStyle Collection • Twilight-II-B • 2108-900 Rev. G • 8/07 21
12
11
10
9
8
7
6
13-5/8
12-5/8
11-5/8
10-5/8
9-5/8
8-5/8
7-5/8
HOOD
NON-COMBUSTIBLE BOARD
(SUPPLIED ON APPLIANCE)
INDOOR SIDE ONLY
CEILING
35-3/4
A. Mantel Projections
Figure 8.1 shows the minimum vertical and corresponding
maximum horizontal dimensions of appliance mantels or
other combustible projections above the top front edge of
the appliance.
8
8
Finishing
B. Facing Material
Fire Risk.
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
Modifying or covering grilles could cause
temperature rise and re hazard.
Finishing materials must not interfere with:
• Air ow through grilles or louvers.
Operation of louvers or doors.
Access for service.
Inside Facing Material
• May install combustible materials up to specified
clearances on top, front and sides of appliance.
Seal joints between nished wall and appliance top and
sides with 300º F (140º
C) minimum sealant.
• Leave space so bottom grille can be lowered for trim
door removal.
41-7/8 in.
2-3/4 in.
NON-COMBUSTIBLE ZONE
Figure 8.1 Indoor Clearances to Mantels or other
Combustibles above Appliance
Note: Measurements
are in inches.
Interior
View
Figure 8.3 Non-combustible Zone (Interior)
Outside Facing Material
Figure 8.2 Clearances to Combustible Mantel Leg or Wall
Projections (Acceptable on both sides of opening.)
Top View
WARNING
MEASURED
FROM CORNER
FIREPLACE
HOOD
½ IN.
Figure 8.4 Exterior View - Minimum Clearances
Vinyl Non-vinyl
A 36 in. 12 in.
B 64-5/16 in. 35-5/16 in.
OVERHANG
A
A
A
B
SIDING
SIDING