Step 1.
Determine the desired location of the appliance. Check to
ensure that wall studs or roof rafters are not in the way when
the venting system is attached. If this is the case, you may
want to adjust the location of the appliance.
F. Horizontal Termination
Figure 5.4
Figure 5.3
Rear Installations for Use with
Rear Vent Kit
Type B -
Up & Out Installations for Top
Vent Configurations
Type A -
Type C - 45° Elbow in Corner Installation
90º ELBOW
PIPE LENGTH
PIPE LENGTH
WALL THIMBLE
center line
WALL THIMBLE COVER
TERMINATION CAP
CENTER LINE
W AL L THIMBL E
W AL L THIMBLE COVER
17-3/4 in.
(451mm)
TERMINATION CAP
45° Elbow
2 in. (51mm) Clearance from stove
corner to combustible wall.
2 in. (51mm)
Clearance from stove
corner to combustible
wall
Wall Thimble
Step 1.
Determine the desired location of the appliance. Check to
ensure that wall studs or roof rafters are not in the way when
the venting system is attached. If this is the case, you may
want to adjust the location of the appliance.
Step 2.
Direct vent pipe is designed with a locking connection. To
connect the venting system to the appliance flue outlet, a
twist-lock adapter is built into the appliance at the factory.
Wall thickness may vary. Remember to include wall
thickness in minimum clearances when figuring venting
lengths for your installation needs.
Note: Female ends of direct vent pipe/elbows are
designed to slide straight onto the male ends of adjacent
pipes by orienting the pipe indentations so they match and
slide into the entry slots on the male ends, see Figure 5.4.
Push the pipe sections completely together, then twist-lock
one section clockwise approximately one-quarter turn, until
the two sections are fully locked. The female locking lugs
may not be visible from the outside. They may be located by
examining the inside of the female ends.
Fire Hazard.
Exhaust Fume Risk.
Impaired Performance of Appliance.
WARNING
Ensure vent components are locked together correctly.
Pipe may separate if not properly joined.