Hearth and Home Technologies FL92 Indoor Fireplace User Manual


 
19
B. Clearances
WARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles as speci ed in Fig-
ure 6.2. DO NOT pack required air spaces with insulation or other materials.
(insulation)
0 in. to level
of standoffs
Attic
Insulation
Shield
(ceiling)
(roof)
(attic)
(ceiling)
Ceiling Firestop
Offset/Return (secured
with hanger straps)
Storm Collar
Roof Flashing
1/2 in. (13 mm) to
back of appliance
Must have 2 in. (51 mm)
minimum clearance
to header
0 in.
to floor
2 in. (51 mm) min.
Shaded areas
represent
2 in. (51 mm) min.
air space clearance
required around pipe
Combustible Object
48 in.
1219 mm
Figure 6.2 Air Space Clearances
Heatilator • Multi-Sided Woodburning Fireplace • 34955 • Rev V • 11/08