Locate outside air kit on one side of replace.
Figure 7.19 Close-up of Outside Air Kit
Open door (raise handle up to open, refer to Figure 2.1
for location of handles).
Bend the four tabs out at 90 degrees. See Figure 7.20.
Figure 7.20 Bending Tabs on Outside Air Kit Collar
Position ring over tabs and screw in place. See
Figure 7.21.
Repeat for other side.
Figure 7.21 Attaching Outside Air Kit Collar
Check the operation by moving the outside air control
handles up and down (refer to Figure 2.1).
Mark and cut out a 4 in. (102 mm) hole in the building
side for air entry.
Install the outside air hoods in the sidewall of the
structure, ush with the building’s exterior.
• Assemble the exible duct (not supplied) between the
collar and the outside air hood. Secure into position with
the supplied wire ties.
Check for light leaks with a ashlight and seal with duct
tape and/or insulation.
Heat & Glo • EXCLAIM-50 • 4013-041 • Rev U • 11/08