B. Tempered Glass Speci cations
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous
locations such as bathtub enclosures as de ned by the
Consumer Product Safety Commission (CPSC). The
tempered glass has been tested and certi ed to the
requirements of ANSI Z97.1 and CPSC 16 CFR 1202
(Safety Glazing Certi cation Council SGCC# 1595 and
1597. Architectural Testing, Inc. Reports 02-31919.01 and
02-31917.01).
This statement is in compliance with CPSC 16 CFR
Section 1201.5 “Certi cation and labeling requirements”
which refers to 15 U.S. Code (USC) 2063 stating “…Such
certi cate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
C. BTU Speci cations
MODELS: CD4236MR, CD4236MLR, CD4236MIR, CD4236MILR
CD4842MR, CD4842MLR, CD4842MIR, CD4842MILR
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Vented Gas Fireplace Heaters
STANDARD: ANSI Z21.88-2005•CSA2.33-2005•UL307B
This product is listed to ANSI standards for “Vented Gas
Fireplace Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Fireplaces for Use
at High Altitudes”.
E. Non-Combustible Materials Speci cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 ºC and UL763 shall be
considered non-combustible materials.
F. Combustible Materials Speci cation
Materials made of or surfaced with wood, compressed
paper, plant bers, plastics, or other material that can ig-
nite and burn, whether ame proofed or not, or plastered
or unplastered shall be considered combustible materials.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemental
room heat or as a decorative appliance. It should not be fac-
tored as primary heat in residential heating calculations.
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility or
authorities having jurisdiction.
When installing above 2000 feet elevation:
In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
In CANADA: Reduce input rate 10% for elevations
between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.
Check with your local gas utility to determine proper
ori ce size.
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
1
1
Listing and Code Approvals
A. Appliance Certi cation
Caliber CD Mesh Series CD4236M CD4842M
Standing Pilot or IPI
Max/Min Input Rate (NG) 30,000/20,000 33,000/22,000
Ori ce Size (NG) .104 in./2.64 mm .109 in./2.77 mm
Max/Min Input Rate (LP) 29,500/20,000 32,500/20,500
Ori ce Size (LP) .065 in./1.65 mm .067 in./1.70 mm