C. Before Your First Fire
1. First, make sure your appliance has been properly
installed and that all safety requirements have been met.
Pay particular attention to the fire protection, venting and
thermostat installation instructions.
2. Double check that the ash pan and firebox are empty!
3. Check the position of the thermocouple, located above
the firepot, and make sure that it protrudes approximately
3/4 inch (19mm) into the firepot. IMPORTANT DETAIL:
The tip of the thermocouple must be in contact with
the inside end of the thermocouple cover.
4. Close the front door.
D. Starting Your First Fire
1. A thermostat is required for proper operation of this
appliance, except for corn. At this time, fill the hopper
with pellets, set the thermostat to its lowest setting. Plug
the power cord into nearby outlet.
2. The exhaust blower will stay on for approximately 18
minutes even though the thermostat is not calling for
heat. This is normal.
3. L
ocate the heat output control switch mounted on the back
of the appliance in the upper right corner. See Figure 21.1
on page 21. Turn it to the “high” setting by pushing the top
of the control switch in and then adjust the thermostat to
its highest setting. Open the right side panel and the red
call light located behind the control box will be on. See
Figure 22.1. This indicates the thermostat is calling for
heat.
4.
The fuel feed system and the igniter should
now
be on.
5. For your first fire it will be necessary to press the reset
button once approximately 2 minutes after start up and
again in 5 minutes. This will fill the feed system and allow
the appliance to begin dropping pellets. The appliance
will continue to run as long as the thermostat is calling
for heat.
6. Once the appliance has ignited, let it burn for approximately
15 minutes, then set the thermostat to the desired room
temperature. Adjust the heat output control switch to the
desired setting.
E. Fire Characteristics
A properly adjusted fire with the heat output control switch
set on “high” has a short active flame pattern that extends
out of the firepot approximately 4 inches (102mm). If the fire
has tall flames with black tails and seems somewhat lazy,
the feed rate will need to be reduced. This is done by sliding
the fuel adjustment control rod down, which will reduce the
feed. If the fire is not 4 inches (102mm) tall, slide the fuel
adjustment control rod up to increase the feed. A medium
and low setting will give a shorter flame. The flame will rise
and fall somewhat. This is normal.
The feed adjustment control rod is factory set, and should
be adequate for most fuels. However, if the flame height is
too high or too low, you will need to adjust the feed rate. Wait
until the appliance has been burning for 15 minutes before
making your adjustments and a
llow 15 minutes for feed
adjustment to take effect.
F. Feed Rate Adjustment Instructions
1. Loosen the set screw 1/4 to 1/2 turn during set-up
of appliance. This will allow movement of the feed
adjustment control rod. Do not re-tighten set screw.
Figure 22.2.
2. Loosen the wing nut. Figure 22.3.
3. Adjust the feed adjustment control rod upward towards the
"+" symbol to increase the feed rate and flame height or
down towards the "-" symbol, to decrease the feed rate
and flame height. Figure 22.3.
4. Re-tighten the wing nut.
Set Screw
Fuel Adjustment
Control Rod
Wing Nut
Increase
Decrease
Figure 22.3
Red Call Light is
located on top of
Junction Box behind
the Control Box.
Control
Box