Hearth and Home Technologies BIR42-B Indoor Fireplace User Manual


 
28
ROOM ABOVE (non-insulated ceiling)
ATTIC ABOVE (insulated ceiling)
B
A
Ceilng firestop from
bottom
Ceiling firestop from
top
Note: Use same dimensional lumber for framing
ceiling firestop and joists.
Figure 8.5 Installing the Ceiling Firestop
Install a ceiling restop whenever chimney penetrates
ceiling/oor.
Mark and cut an opening in ceiling as shown in
Figure 8.5.
Frame the opening with the same size lumber used in the
ceiling joists.
Nail the ceiling restop to the bottom of the ceiling joists
when there is a room above/
Use an attic insulation shield if the ceiling is insulated. The
ceiling restop may then be attached above or below the
joists. Refer to Figure 8.6 and 8.7.
D. Install Ceiling Firestops
CAUTION! Risk of Fire! Ceiling restops must be used
whenever the chimney penetrates a ceiling/oor.
Chase construction requires ceiling restops at each oor
or every 10 ft (3.05 m) of clear space.
The ceiling restop slows spread of re and reduces cold
air inltration.
WARNING! Risk of Fire! DO NOT seal area between
restop opening and chimney pipe except where they
enter the attic or leave the warm-air envelope of the
home (use 600° F sealant).
Heatilator • Birmingham BIR42-B • 4059-681 • 11/11
Catalog #
A B
in. mm in. mm
FS538 17 432 17 432
FS540 17 432 26 660