Hearth and Home Technologies 43ST-ACC Stove User Manual


 
September 1, 2008
7037-135E
Page 11
4300 Wood Stove Series (ACC)
R
B. Clearances to Combustibles (UL and ULC)
BACKWALL / SIDEWALL
CORNER INSTALLATION
90° OFF TOP
UP & OUT CEILING
CLEARANCE
STOVE TO CEILING
CLEARANCE
ALCOVE TOP VIEW
A
B
ALCOVE SIDE VIEW
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction
Fire Risk.
Comply with all minimum clearances to
combustibles as specied.
Failure to comply may cause house re.
WARNING
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.
A B C D E F G H
INSTALLATION: Full Vertical OR Horizontal with Minimum 2 FT Vertical Off Stove Top
SINGLE WALL PIPE
Flat Top Model 15.5 (394) 11.75 (298) 24.5 (622) 14.5 (368) 10 (254) 17.5 (445) 53.5 (1359) 12 (305)
Step-Top Model 15.5 (394) 11.75 (298) 24.5 (622) 14.5 (368) 2 (51) 12 (305) 49.5 (1283) 12 (305)
DOUBLE WALL PIPE
Flat Top Model 9 (229) 5.25 (133) 24.5 (622) 14.5 (368) 10 (254) 17.5 (445) 53.5 (1359) 12 (305)
Step-Top Model 7.5 (191) 3.75 (95) 22 (559) 11.75 (298) 2 (51) 12 (305) 49.5 (1283) 5 (127)
INSTALLATION: 90° Elbow Off Top of Stove Through Backwall
DOUBLE WALL PIPE
Flat Top Model 8.5 (216) 6 (152) 24.5 (622) 15 (381) 10 (254) 17.5 (445) 53.5(1359) N/A
Step-Top Model 7.5 (191) 4 (102) 19 (229) 9 (229) 2 (51) 12 (305) 49.5 (1283) N/A
INSTALLATION: ALCOVE
Six inch (6") (152mm) diameter listed Double Wall air insulated connector pipe with UL103 HT* listed
factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor). Maximum depth of Alcove
shall be no more than 48 inches (1220mm) with a minimum height of 49.5 inches (1283mm) to top of unit, and the referenced clearances.
*In Canada must comply with CAN/ULC-S269 M87 for the 650
o
C Factory-built chimney.
DOUBLE WALL PIPE
Flat Top Model 13 (330) 10 (254) 24.5 (622) 14.5 (368) N/A N/A 53.5 (1359) 12 (305)
Step-Top Model 7.5 (191) 3.75 (95) 22 (584) 11.75 (298) N/A N/A 49.5 (1257) 5 (127)
NOTE: Service Space
In order to replace the tube channel assembly a clearance
of 19 inches (48mm) is required on the right side of stove
in order to remove the tubes with the stove in place.
If space is not available, the stove will have to be discon-
nected from the chimney to proceed with the tube replace-
ment. See Figure 36 on page 36.