Hearth and Home Technologies 299-900D Indoor Fireplace User Manual


 
Hearth & Home Technologies • Heat-Zone-240V Air Duct Kit • 299-900D • 7/102
FLOOR REGISTER
TWO DUCT KITS
WALL REGISTER
WALL REGISTER
WALL REGISTER
CEILING REGISTER
Figure 2
Possible Air Duct Runs/Locations
2. The Heat-Zone 240V kit is tested and safe when installed
in accordance with this installation manual. This kit is
carefully engineered and must be installed only as speci-
ed. Modifying the kit or any of its components will void
the warranty, and may possibly cause a re hazard.
3. CAUTION: Installation of this appliance should only be
carried out by an authorized person. All relevant codes
and regulations laid down by the gas piping authorities,
municipal building regulations, electrical wiring regula-
tions and the requirements of the AS5601 Gas Instal-
lation code must be observed.
4. Plan the location of the heater and the warm air duct
run(s).
MAXIMUM Duct Run = 6 M for useful heat output.
MINIMUM Duct Run = NA - for runs out from the heater
to adjacent room OR down to the room below.
MINIMUM Duct Run = 787 mm top of heater to room
above.
COVER
PLATE
DUCT
COLLAR
6000 SERIES
XLR-AU
Installation
1. Remove the cover plate from the side of the heater and
discard it.
2. Center the duct collar around the exposed hole and
attach it to the heater with 3 screws. NOTE: Do this
BEFORE nal positioning of the heater. See Figure 3.
Figure 3