Hearth and Home Technologies 21M-ACC Stove User Manual


 
Page 10
7039-131F
September 1, 2008
R
2100 Millennium Wood Stove (ACC)
B. Clearances to Combustibles (UL and ULC)
BACKWALL / SIDEWALL
A
B
C
D
E
F
E
F
CORNER INSTALLATION
STOVE TO CEILING
CLEARANCE
C
D
ALCOVE TOP VIEW
G
A
B
ALCOVE SIDE VIEW
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction
Fire Risk.
Comply with all minimum clearances to
combustibles as specied.
Failure to comply may cause house re.
WARNING
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.
A B C D E F G H
INSTALLATION: Full Vertical
SINGLE WALL PIPE 15 (81) 11 (279) 21.5 (546) 1 (0) 8.5 (216) 17(42) 56 (1422) N/A
DOUBLE WALL PIPE 8.75(222) 5.75 (146) 20 (508) 10.5 (267) 7.5 (191) 16 (406) 4 (1092) N/A
INSTALLATION: Horizontal with Minimum 2 Foot Vertical Off Stove Top
SINGLE WALL PIPE 14 (56) 10 (254) 20.5 (521) 12 (05) 8.5 (216) 17 (42) 56 (1422) 9.5 (241)
DOUBLE WALL PIPE 9.5 (241) 5.5 (140) 21.5 (546) 1 (0) 7.5 (191) 16 (406) 4 (1092) 5 (127)
INSTALLATION: ALCOVE
Six inch (6") (152mm) diameter listed double wall air insulated connector pipe with UL
10 HT listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark
arrestor). Maximum depth of alcove shall be no more than 48"(1220mm) with a minimum height of 4" (1092mm) to top
of unit, and the referenced clearances.
DOUBLE WALL PIPE 9.5 (241) 5.5 (140) 21.5 (546) 1 (0) N/A N/A 4 (1092) 5 (127)
NOTE: Service Space
In order to replace the tube channel assembly a clearance
of 17 inches (42mm) is required on the right side of stove
in order to remove the tubes with the stove in place.
If space is not available, the stove will have to be discon-
nected from the chimney to proceed with the tube replace-
ment.