Hatco Hatco 3CS2 Electric Heater User Manual


 
10
Form No. HHM-1103
OPERATION
NOTE: If steps 6-9 are interrupted or no changes
are made for 15 seconds the controller will go back
to its original setting without accepting the change.
NOTE: If unit displays “E1” or “E2” the internal
water sensing probe is out of temperature range.
If this occurs contact Hatco Parts and Service Team
or an Authorized Service Agent in your area
for assistance.
CHANGING TEMPERATURE
DISPLAY FROM FAHRENHEIT (F°)
TO CELSIUS (C°)
WARNING
To avoid any injury or damage to the unit use
only Authorized Hatco Service Agents to perform
any temperature display changes.
A dipswitch panel consisting of four switches is located
behind the front graphic overly.
Switch 2 is used to change the temperature display
from F° to C°.
1. Turn the power switch to the OFF position
at the fuse disconnect switch/circuit breaker
and unplug power cord (if equipped) from
the power source and allow unit to cool.
2. Remove front control compartment cover.
3. Move dipswitch “2” to the right to change
the display from Fahrenheit (F°) to Celsius (C°).
4. Re-install control compartment cover.
5. Restore power supply and turn power switch to ON.