Install the pop-up drain
Remove the plunger assembly.
Unscrew the drain outlet flange from the
tee.
Unscrew the tailpiece from the tee.
Wrap the threads with Teflon tape
and replace.
Install the flexible sealing gasket on the
flange. Sit it in the sink outlet.
From below, install the black mack gasket,
white friction ring, and retainer nut to the
flange. Do not tighten the nut against the
bottom of the sink at this time.
Thread the tee and tailpiece to the flange.
The pivot must face the faucet. If neces-
sary, turn the drain assembly.
Tighten the retainer nut.
Sit the plunger assembly in the drain.
Install the horizontal rod through the pivot
ball seals and into the tee so that the end
goes through the loop in the bottom of the
height adjuster. The two pivot ball seals
should surround the pivot ball.
Slide the link over end of pull rod. Tighten
screw.
Slide one end of spring clip over end of
horizontal rod. Slide link over end of hori-
zontal rod. Test motion of drain plunger.
Reposition link as necessary. There are
multiple holes in the link -- the horizontal
rod may go through any of the holes.
When satisfied with the action of the drain,
slide the other end of the spring clip over
the end of the horizontal rod.