Hans Grohe 0657000 Plumbing Product User Manual


 
4
Rough-in
Installation on a flat wall Installation in 90° corner
Seal the wall around the
nipples with waterproof
sealant.
Failure to seal the wall
can lead to possible water
damage.
English
This unit can be installed on a flat wall or
in a 90° corner. Instructions for installa-
tion on a flat wall begin on page 5. Go
to page 8 if the panel is to be installed in
a corner.
Ensure that you have a minimum
83" ceiling height from the stand-
ing surface.
Stub out 1/2" NPT male nipples for the
hot and cold water supplies at the loca-
tions shown on the appropriate rough-in
diagram. The nipples should extend 5/8"
outside the surface of the finished wall.
Install the wall surface and make the wall
watertight before installing the panel. The
panel hangs on the finished wall.