Installing Unit into A Window
Window Opening Requirements
The air conditioner is designed to fit into double or single hung sash type windows. Each of the
units comes with an installation kit that provides adjustable mounting louvers, to fill the gaps
between the sides of the unit, and the window frame. The chart below reflects the dimensions of
the units with, and without installation kits. Measure your window opening width and compare
it to the chart below to ensure that it meets the minimum and maximum window width requirements.
Model
A(inch)
Dimension
B(inch)
C(inch)
D(inch) Max
Case High
Case Width
D(inch) Min
Case Depth
HWR10XC5, HWR12XC5, ESA3105, ESA3125
HWR10XC5, HWR12XC5,ESA3105, ESA3125
Models HWR10XC5, HWR12XC5, ESA3105, ESA3125
Unpack unit on floor next to installation location.
1. Open the inlet grille by pulling the exposed door on
the top of the unit and remove the screw which fasten the
front panel. (Fig. A)
2. Remove the front panel and rotate it to B position.
Separate operation panel from the front panel by pushing
the tabs. (Fig. B)