Haier HSU-12HS03/R2DB Air Conditioner User Manual


 
. Change the set temperature. With temperature adjusting function
. The wind volume is the automatic medium
. When in frost removing mode, the outdoor unit does not accept the
communication signal for powerful running
. After 15 minutes of powerful running, the compressor can not be off within 10
minutes
4-0-2. Powerful cooling
Change the set temperature. With temperature adjusting function
. The wind volume is the automatic strong
. After the compressor starts, there will be no low-intense running protection within
3 minutes
4-0-3 There is no powerful mode for wind-sending and moisture removing
5.Silent running
. Send the silent running signal to the outdoor unit
5-0-1. Silent hearing
The wind volume is SSLO after the compressor is on
The wind volume will be kept SSLO within 20 seconds after the compressor stops
and then changes to weak
5-0-2. Silent cooling
The wind volume is SSLO
5-0-3 There is no silent mode for moisture removing and wind-sending.
6. Timed running
.
Set the time duration according to the time difference between the clock for
timing and the current clock
. In timing mode, the display panel will flash the light at fixed times
6-0-1. Timed OFF
When this function is set, operation modes on the panel display will not change.
The timing icon will show and the operation stops when the set time comes.
6-0-2. Timed ON
When this function is on, the panel display will only show a timing icon. The unit
will operate as the set mode when the time comes.
6-0-3 Timed ON/OFF
The unit will start operating or stop according to the order of your setting.
7. Automatic running
7-1.
Automatic running mode
Under this
mode, the MCU will choose the work mode according to the room
temperature so as to keep the set termperature ( set 23 for heating mode and
26 for cooling mode)
When the unit is powered on for the first time and the the room termperature is equal to or
below 23 , it will start the heating mode or the cooling mode when the room temperature is
higher than 23
Enter into the heating mode and follow the heating process(supposed temperature 23 ).
When the temperature is high enough to stop the compressor, the compressor stops and there
30
Model:
HSU-12HS03/R2(DB)
HSU-09HS03/R2(DB)Domestic Air Conditioner