Haier HSU-12HQA03/R2(DB) Air Conditioner User Manual


 
Operation
AUTO COOL DRY FAN HEAT
2.Select operation mode
Press MODE button. For each press, operation mode
changes as follows:
Remote controller:
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Base Operation
Remote controller
Air Flow Direction Adjustment
Vertical flap
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
(Auto swing)
1.Status display of air flow
When restart after remote turning off, the remote
memorize the previous
2.Left and right air flow adjustment
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
adjusted to left or
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY
otherwise, condensate water might occur.
Emergency Operation:
temperature is below 16
o
C, do not use it in the
Test operation:
Use this switch in the test operation when the room
normal operation.
your finger from the switch: the cooling
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice,
release
Test operation switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
Emergency operation and test operation
Use this ope
r
ation only when the remote controller
is defective or lost.
When the emergency operation switch is
pressed,the" Pi "sound is heard once
, which
the start of this operation.
In this operation, the system automatically selects
the
operation modes
,cooling or fan or heat,
according to the room temperature.
.
It is not possible to operate in dry mode.
Room
temperature
Operation
mode
Designated
temperature
Timer
mode
Air flow
ABOVE 24
O
C
BELOW 24
O
C
COOLING
HEAT
2
4
O
C
2
4
O
C
NO
NO
AUTOMATIC
AUTOMATIC
(C
ooling only uint
Room temperature
Operation
mode
Designated
temperature
Timer
mode
Air flow
BELOW 2
4
O
C
FAN
2
4
O
C
NO
AUTOMATIC
at air outlet if all vertical louvers are
right.
mode ,
controller will automatically
Note:
set swing position.
means
Operation
Mode
AUTO
Remote
Controller
Note
COOL
DRY
HEAT
FAN
In DRY mode, when room temperature becomes
lower than temp.setting+2
o
C, unit will run
intermittently at LOW speed regardless of FAN
Under the mode of auto operation, air conditioner
will automatically select Cool or Heat operation
according to room temperature. When FAN is set
to AUTO, the air conditioner
automatically adjusts
temperature.
the fan speed according to room
In FAN operation mode, the unit will not operate in
COOL or
HEAT mode but only in
FAN mode ,
AUTO is not available in
FAN mode.
And temp.
setting is disabled. In FAN mode, sleep operation
setting.
is not available.
Pi
emergency
operation
switch
test operation
switch
Pi
Pi
Press FAN button. For each press, fan speed
follows:
Remote controller:
Press button
Every time the button is pressed, temp.setting
increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will
decrease rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
LOW
MED
HI
AUTO
/
changes as
3
1
4
2
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
Pos.7
Pos.8
For each press of button, remote controller
displays as follows :
remote controller: